Reference Guide
Recommended
Response
Action
Turn on the server, if necessary, before requesting a power cycle operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8570
Message Unable to communicate to the iDRAC, when trying to power cycle the server arg1 .
Arguments
• arg1 = slot number
Detailed
Description
The Chassis Management Controller is not able to communicate with the iDRAC
on the server identified in the message. Therefore, the server could not be power
cycled. This situation may occur when iDRAC is rebooting.
Recommended
Response
Action
Wait for few minutes, and then retry the operation. If the issue persists, do one of
the following: 1) Reset the iDRAC, 2) Perform a Virtual Reseat of the server, 3)
Remove and re-insert the server.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1132