Reference Guide

Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8568
Message Server arg1 did not gracefully shutdown before the timer expired.
Arguments
arg1 = slot number
Detailed
Description
The server identified in the message did not gracefully shutdown before the CMC
shutdown timer expired. This happens if the server did not show power off status
change within 60 seconds after the operation was initiated, or if the OS in the
server has not successfully shutdown.
Recommended
Response
Action
Check if the OS in the server identified in the message has successfully shutdown,
if not, manually complete the shutdown or wait for the shutdown to complete
normally. If the issue persists, perform a forced power down of the server identified
in the message.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8569
Message Unable to power cycle the server arg1 because the server is off.
Arguments
arg1 = slot number
Detailed
Description
The requested power cycle operation cannot be performed when the server is not
turned on. The server should be already turned on for the power cycle operation to
be successful.
1131