Reference Guide

Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8565
Message Unable to turn off the Server arg1 due to iDRAC communication issue.
Arguments
arg1 = server number
Detailed
Description
The Chassis Management Controller is unable to communicate with the iDRAC
service processor for the Server identified in the message and the Server could not
be turned off. This situation may occur when iDRAC is rebooting.
Recommended
Response
Action
Do the following: 1) Wait for a few minutes for the iDRAC service processor to
complete startup. 2) Retry the operation. 3) If the issue persists, reset the iDRAC
and wait a few minutes for the iDRAC startup to complete before retrying the
operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1129