Reference Guide
Server
Administrator
Trap ID
Not Applicable
PWR8563
Message Unable to turn on Server arg1 due to I/O fabric inconsistency.
Arguments
• arg1 = server number
Detailed
Description
The Server identified in the message did not turn on due to a fabric mismatch
between the I/O Module and the Mezzanine card on the Server.
Recommended
Response
Action
Make sure that the hardware compatibility between the I/O Module (IOM) and the
Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct
component compatibility.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8564
Message Unable to turn on the Server arg1 because the power request exceeded the System
Input Power Cap.
Arguments
• arg1 = slot number
Detailed
Description
The server identified in the message was not turned on because the available
power is less than the requested power.
Recommended
Response
Action
Utilize the Chassis Management Controller web interface to check the System
Input Max Power Capacity Power and server power requirements. If sufficient
power is available, retry the operation. Otherwise, increase the System Input Power
Cap value.
Category Audit
1128