Reference Guide
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8560
Message Unable to turn on I/O Module arg1 due to insufficient chassis power.
Arguments
• arg1 = IOM slot name
Detailed
Description
Unable to turn on the I/O Module identified in the message due to insufficient
chassis power.
Recommended
Response
Action
Utilize the Chassis Management Controller (CMC) web interface to check available
power and I/O Module power requirements. If sufficient power is available, restart
the CMC and retry the operation. If sufficient power is not available due to an
insufficient number of PSUs, add additional PSU(s) and reinsert the I/O Module.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8561
Message Unable to power on server arg1 because of iDRAC communication issue.
Arguments
• arg1 = server number
1126