Reference Guide
Arguments
• arg1 = slot number
Detailed
Description
The Server identified in the message was shutdown due to insufficient power.
Recommended
Response
Action
No response action is required.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8557
Message The System Input Power Cap is too low to be enforced using the current Power
Supply configuration.
Detailed
Description
The current Power Cap setting cannot be enforced. This may be the result of
changing the redundancy mode or by changing the PSUs. The power cap setting
must be increased to be usable.
Recommended
Response
Action
Increase the Power Cap value. To increase the Power Cap do one of the following:
1) Using CMC Web interface: Select "Chassis Overview" -> Power -> Configuration
and then adjust System Input Power Cap values. 2) Run the following RACADM
command at the command line interface: "config -g cfgChassisPower -o
cfgChassisPowerCap <value>". Try setting the power cap above the lower bound
displayed on the power configuration page.
Category System Health
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 2274
LCD Message No LCD message display defined.
Initial Default None
1124