Reference Guide

Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8555
Message Chassis Management Controller unable to turn on arg1 - arg2 at priority arg3
because of insufficient power. Minimum power needed is arg4 AC Watt, but only
arg5 AC Watt is available.
Arguments
arg1 = component name
arg2 = slot number
arg3 = priority number
arg4 = min power
arg5 = avaialble power
Detailed
Description
The request to turn on the component identified in the message was not
successful because insuffficient power is available at the identified priority for the
component.
Recommended
Response
Action
Make sure there is enough power supply to distribute power. Using the CMC Web
UI, go to Chassis Overview > Power > Power Budget Status. In the Total Input
Power Available For Allocation field view the available power. To add more power,
insert more PSUs or remove unused components from the chassis.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8556
Message Server arg1 was shutdown due to insufficient power.