Reference Guide

Recommended
Response
Action
Make sure there is enough power supply to distribute power. Using the CMC Web
UI, go to Chassis Overview > Power > Power Budget Status. In the Total Input
Power Available For Allocation field view the available power. To add more power,
insert more PSUs or remove unused components from the chassis. Contact your
service provider for information on the power required for the component
identified in the message.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8554
Message Chassis Management Controller is unable to send power allocation information to
arg1 - arg2 at priority arg3 .
Arguments
arg1 = component name
arg2 = component id
arg3 = priority number
Detailed
Description
This situation occurs if the iDRAC is found to be turned off after power allocation
information is sent by the CMC or if the communications between the CMC and
iDRAC is non functional.
Recommended
Response
Action
Perform a Virtual Reseat of the component identified in the message. Using the
CMC Web UI, go to Chassis Overview > Troubleshooting > Reset Components, and
then select slot for the component identified in the message and apply the Virtual
Reseat.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
1122