Reference Guide
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8544
Message Chassis Management Controller turned off the Server arg1 because of insufficient
power at inventory.
Arguments
• arg1 = slot number
Detailed
Description
Insufficient power is available for the server identified in the message to function.
The server will be turned off until there is sufficient power available.
Recommended
Response
Action
Make sure there is enough power supply to distribute power. Using the CMC Web
UI, go to Chassis Overview > Power > Power Budget Status. In the Total Input
Power Available For Allocation field view the available power. To add more power,
insert more PSUs or remove unused components from the chassis.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8545
Message Chassis Management Controller turned off the server arg1 because of incorrect
power data retrieved from iDRAC at inventory.
Arguments
• arg1 = slot number
1117