Reference Guide

Server
Administrator
Trap ID
Not Applicable
PWR8527
Message Server slot power priorities changed - reallocating power.
Detailed
Description
Server slot power priorities were changed. Power to servers is being reallocated.
Recommended
Response
Action
No response action is required.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8528
Message Unable to set Max Power Conservation Mode because the Server Based Power
Management mode is enabled.
Detailed
Description
The Max Power Conservation Mode can be enabled only when Server Based Power
Management Mode is disabled.
Recommended
Response
Action
The Max Power Conservation Mode can be changed when Server Based Power
Management mode is disabled. Using the CMC Web UI, navigate to the Chassis
Overview > Power > Configuration page, then uncheck the Enable Server Based
Power Management checkbox. Retry the operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
1108