Reference Guide
PWR8509
Message Unable to change the server power priority because Server Based Power
Management mode is enabled.
Detailed
Description
Unable to change the server power priority because Server Based Power
Management mode is enabled.
Recommended
Response
Action
The server power priority can be changed once Server Based Power Management
mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview >
Power > Configuration page, then uncheck the Enable Server Based Power
Management checkbox. Retry the operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8510
Message Unable to set chassis power property arg1 .
Arguments
• arg1 = property name
Detailed
Description
Unable to set the chassis power identified in the message.
Recommended
Response
Action
Retry the operation. If the issue persists, contact your service provider.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
1099