Reference Guide

Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8504
Message Chassis power button is pressed, but the button is disabled.
Detailed
Description
The chassis power button press is detected but the button has been disabled.
Recommended
Response
Action
The chassis power button is disabled. To enable the chassis power button use the
CMC RACADM command line interface, CMC Web interface. Using the command
line, enter "racadm config -g cfgChassisPower -o cfgChassisPowerButtonEnable
1". Using the Web interface, click Chassis Overview > Power > Configuration. Clear
the Disable Chassis Power Button check box.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR8505
Message The Dynamic Power Supply Engagement feature was not successfully enabled.
Detailed
Description
The Dynamic Power Supply Engagement feature was not successfully enabled.
Recommended
Response
Action
Restart the Chassis Management Controller and retry the operation. To restart the
Chassis Management Controller, using the WEB UI, go to Chassis Overview >
Power > Control, select the Reset CMC option, and then click Apply.