Reference Guide
Server
Administrator
Trap ID
Not Applicable
PWR2253
Message Unable to turn on the server because a PCIe card or Mezzanine card is not
installed.
Detailed
Description
The server did not turn on because a PCIe card or Mezzanine card is not installed.
Recommended
Response
Action
Install a PCI or Mezzanine card in the appropriate slot and retry the operation.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log;None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR2254
Message The use of 110V is unacknowledged and the chassis cannot grant power on
permission to the server.
Detailed
Description
The use of 110V is unacknowledged for the chassis and the chassis cannot grant
power on permission to the server.
Recommended
Response
Action
Check for unacknowledged use of 110V and change to acknowledged. Using the
Chassis Management Controller (CMC) web interface, select Chassis
Overview>Power>Configuration and then check the 110V Acknowledge field. Retry
the operation to turn on the server.
Category Audit
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log;None
1085