Reference Guide

Recommended
Response
Action
DIsable Dynamic Power Supply Engagement (DPSE) and retry the operation.
Category System Health
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR216
Message Unable to enable Extended Power Performance, because Redundancy Policy is set
to Grid Redundancy or No Redundancy.
Detailed
Description
Unable to enable Extended Power Performance, because redundancy policy is set
to Grid Redundancy or No Redundancy.
Recommended
Response
Action
Configure Redundancy Policy to Power Supply Redundancy and retry the
operation. Using the CMC Web GUI, click Power > Configuration. From the
Redundancy Policy drop-down menu, select Power Supply Redundancy.
Category System Health
Subcategory PWR = Power Usage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PWR218
Message Cannot enable the Extended Power Performance (EPP) feature because the Fresh
Air (FA) mode is enabled.