Reference Guide

PSU1002
Message arg1 was removed
Arguments
arg1 = PSU Sensor Name
Detailed
Description
The enclosure detected that a power supply unit was removed and is no longer
functioning in optimal condition.
Recommended
Response
Action
Re-insert the power supply unit into the enclosure. Re-connect the AC power
cable and switch on the power supply unit. Contact technical support if the issue
persists.
Category Storage
Subcategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 4233
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2324
Server
Administrator
Trap ID
100400
PSU1003
Message arg1 is switched OFF.
Arguments
arg1 = PSU Sensor Name
Detailed
Description
The power supply is not providing any power. This may be because the power
supply switch is in the off position or the power supply has failed.
Recommended
Response
Action
Check whether the power switch on the power supply unit is turned off or on. If it
is turned off, turn it on. If the problem is not corrected, verify that the power cord is
attached and functional. See the storage hardware documentation for more
information.
Category Storage
Subcategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 4234