Reference Guide

Recommended
Response
Action
Reconnect the power cable to the power supply unit if it was disconnected.
Restore the input AC power supply. Make sure the power supply is restored to the
enclosure from the mains.
Category Storage
Subcategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 4234
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2312;2313
Server
Administrator
Trap ID
100300
PSU1001
Message arg1 has failed.
Arguments
arg1 = PSU Sensor Name
Detailed
Description
The enclosure detected that a power supply unit has failed.
Recommended
Response
Action
Check for other messages related to the state of the power supply unit/enclosure.
These may help determine the cause of this event. Contact technical support if the
issue still persists.
Category Storage
Subcategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 4233
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1035