Reference Guide
Server
Administrator
Event ID
5353
Server
Administrator
Trap ID
5353
PSU100
Message Power supply arg1 is offline.
Arguments
• arg1 = power supply unit
Detailed
Description
The power supply unit identified in the message is offline, because of the one of
the following reasons: 1) The power supply unit is not correctly seated. 2) The
power cable may not be connected properly or diconnected. 3) The power supply
unit has failed. 4) There is an input power failure.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default OS Log;None
Server
Administrator
Event ID
5303
Server
Administrator
Trap ID
Not Applicable
PSU1000
Message Power supply cable has been removed from arg1 .
Arguments
• arg1 = PSU Sensor Name
Detailed
Description
The power supply unit is not receiving input AC power. The power cable may not
be connected properly or removed. This can happen if there is an AC failure or
problems with the power strip attached to the enclosure power supply.
1034