Reference Guide

Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PSU0912
Message A failure detected on power unit arg1 .
Arguments
arg1 = number
Detailed
Description
Status from the power supply indicates a power supply exception occurred. The
power supply will try to operate in a degraded state. System Performance and
power redundancy may be degraded or lost.
Recommended
Response
Action
Check input power. Re-install the power supply. If problem persists contact
support.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
5354
Server
Administrator
Trap ID
5354