Reference Guide
Severity Severity 3 (Informational)
Trap/EventID 2187
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PSU0039
Message An under current fault detected on power supply arg1 .
Arguments
• arg1 = number
Detailed
Description
Insufficient amount of current to keep power supply operating at a normal levels.
Recommended
Response
Action
1) Remove and re-install the power supply input cord. 2) Check power distribution
or PSU input source for anomalies. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Under current fault detected on PSU <number>. Check PSU.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PSU0040
Message An output under voltage fault detected on power supply arg1 .
Arguments
• arg1 = number
1015