Reference Guide

LCD Message PSU <number> temperature outside of range. Check PSU
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PSU0034
Message An under voltage fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed
Description
This failure may be the result of an electrical issue with cables or subsystem
components in the system.
Recommended
Response
Action
1) Remove and re-install the power supply. 2) Check cables and subsystem
components in the system for damage. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact
method.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message An under voltage fault detected on PSU <number>. Check power source.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PSU0035
Message An over voltage fault detected on power supply arg1 .
Arguments
arg1 = number
1012