Reference Guide

Recommended
Response
Action
Review server product documentation for supported power supplies and power
supply configurations.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Power supply <number> is incorrectly configured. Check PSU.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
5354
Server
Administrator
Trap ID
5354
PSU0007
Message Power supply arg1 is operating at 110 volts, and could cause a circuit breaker fault.
Arguments
arg1 = number
Detailed
Description
A power supply that is designed to operate at 220V, but is connected to a 110V
power source requires additional current for operation. The additional current may
trip circuit-breakers or cause other electrical issues with the input source.
Recommended
Response
Action
Check input power source and cabling. Use recommended input power. Review
the product documentation. If the issue persists, contact technical support. Refer
to the product documentation to choose a convenient contact method.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
1007