Reference Guide

Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PSU0005
Message The power input for power supply arg1 is outside of the allowable range, but it is
attached to the system.
Arguments
arg1 = number
Detailed
Description
The operating requirements for the power supply may be found in product
documentation or on the power supply itself.
Recommended
Response
Action
Verify the input power is within the operating requirements for the power supply.
Category System Health
Subcategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 2186
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
5353
Server
Administrator
Trap ID
5353
PSU0006
Message Power supply arg1 is incorrectly configured.
Arguments
arg1 = number
Detailed
Description
The power supply identified in the message must be supported by the platform.
Generally, multiple power supplies in the server should have the same feature set
and power rating.
1006