Reference Guide

Recommended
Response
Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2362
Server
Administrator
Trap ID
75100
CTL63
Message Previous configuration was found completely missing during time boot onarg1.
Arguments
arg1 = Controller name
Detailed
Description
The controller is unable to retrieve storage configuration saved during last shut
down. This can generally happen if some configured physical disks are removed
from the system when the system was shutdown.
Recommended
Response
Action
Shut down the system. Re-insert the removed physical disks and re-start the
system.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2364
Server
Administrator
Trap ID
75300
CTL64
Message Attempted to import Unsupported Virtual Disk type RAIDarg1onarg2.
Arguments
arg1 = args
93