Reference Guide

Recommended
Response
Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2339
Server
Administrator
Trap ID
75100
CTL58
Message arg1SAS SMP communications errorarg2
Arguments
arg1 = Controller name
arg2 = args
Detailed
Description
The text for this alert is generated by the firmware and can vary depending on the
situation. The reference to SMP in this text refers to SAS Management Protocol.
Recommended
Response
Action
There may be a SAS topology error. See the hardware documentation for
information on correct SAS topology configurations. There may be problems with
the cables such as a loose connection or an invalid cabling configuration. See the
Cables Attached Correctly section for more information on checking the cables.
See the hardware documentation for information on correct cabling
configurations. Verify that the firmware version is supported.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2356
Server
Administrator
Trap ID
75400
90