Reference Guide

6
CPU Event Messages
CPU0000
Message CPUarg1has an internal error (IERR).
Arguments
arg1 = number
Detailed
Description
System event log and OS logs may indicate that the exception is external to the
processor.
Recommended
Response
Action
Review System Event Log and Operating System Logs. If the issue persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
LCD Message CPU <number> internal error (IERR). Contact Support
Server
Administrator
Event ID
5604
Server
Administrator
Trap ID
5604
CPU0001
Message CPUarg1has a thermal trip (over-temperature) event.
Arguments
arg1 = number
Detailed
Description
The processor temperature increased beyond the operational range. Thermal
protection shut down the processor. Factors external to the processor may have
induced this exception.
Recommended
Response
Action
Review logs for fan failures, replace failed fans. If no fan failures are detected,
check inlet temperature (if available) and reinstall processor heatsink.
Category System Health
53