Reference Guide
Server
Administrator
Trap ID
115300
BAT1032
Message The battery temperature onarg1is normal.
Arguments
• arg1 = controller name
Detailed
Description
The battery temperature is within the normal operating range.
Recommended
Response
Action
No response action is required.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2172
Server
Administrator
Trap ID
115100
BAT1033
Message The battery onarg1was removed.
Arguments
• arg1 = controller name
Detailed
Description
The controller cannot communicate with the battery. Either the battery was
removed, or the contact point between the controller and the battery is degraded.
Recommended
Response
Action
Make sure that the battery is present and properly connected. If the battery is
present, wait for a few minutes and re-check if the battery is detected. If the
contact point between the battery and the controller is degraded, you must replace
the battery, the controller, or both. Refer to the storage hardware documentation
for information on how to safely access, or remove. Contact technical support if
the issue persists.
Category Storage
SubCategory BAT = Battery Event