Reference Guide
BAT1030
Message Thearg1battery charge level is normal.
Arguments
• arg1 = Controller name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response
Action
No response action is required.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2170
Server
Administrator
Trap ID
115100
BAT1031
Message The battery temperature onarg1is above normal.
Arguments
• arg1 = controller name
Detailed
Description
The room temperature may be too hot. In addition, the system fan may be
degraded or failed.
Recommended
Response
Action
Verify that the room temperature is normal and that fans are functioning properly.
See the storage hardware documentation for acceptable operating temperatures.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2171
46