Reference Guide

Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2318
Server
Administrator
Trap ID
115300
BAT1025
Message arg1is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments
arg1 = controller name
Detailed
Description
The controller was unable to recover data from the cache. This may indicate data
loss has occurred.
Recommended
Response
Action
Verify that the battery is charged and in good health. See the hardware
documentation for more information. When the battery charge is unacceptably
low, the battery cannot maintain cached data. Data loss may also have occurred,
restoring data from backups may be needed. Verify whether the battery has met its
recharge limit. The battery may need to be recharged. Contact technical support if
the issue persists.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2337
Server
Administrator
Trap ID
115400
BAT1026
Message Thearg1has recovered cached data from the Battery Backup Unit (BBU).
Arguments
arg1 = controller name
43