Reference Guide

VLT403
Message Thearg1sensor state has changed to a warning state with a value ofarg2Volts.
Arguments
arg1 = sensor name
arg2 = voltage
Detailed
Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the
preset warning threshold. This condition can cause system performance issues and
degradation in the moitoring capability of the system.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
board. 3) If the sensor identified is a processor voltage sensor, remove the
processor module and inspect processor socket, and replace if required. If the
issue persists, contact your service provider.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5153
Server
Administrator
Trap ID
5153
VLT404
Message Thearg1sensor detected an error with a value ofarg2Volts.
Arguments
arg1 = sensor name
arg2 = voltage
Detailed
Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the
preset critical threshold. This condition can cause system performance issues and
degradation in the moitoring capability of the system.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
board. 3) If the sensor identified is a processor voltage sensor, remove the
331