Reference Guide
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
board. 3) If the sensor identified is a processor voltage sensor, remove the
processor module and inspect processor socket, and replace if required. If the
issue persists, contact your service provider.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5151
Server
Administrator
Trap ID
VLT402
Message Thearg1sensor has returned to a normal state with a value ofarg2Volts.
Arguments
• arg1 = sensor name
• arg2 = voltage
Detailed
Description
The voltage sensor identified in the message has returned to a normal state.
Recommended
Response
Action
No response action is required.
Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5152
Server
Administrator
Trap ID
5152
330