Reference Guide
27
VLT Event Messages
VLT400
Message Thearg1sensor has failed with a valuearg2Volts.
Arguments
• arg1 = sensor name
• arg2 = voltage
Detailed
Description
A voltage sensor identified in the message may have failed. This condition can
cause system performance issues and degradation in the moitoring capability of
the system.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
board. 3) If the sensor identified is a processor voltage sensor, remove the
processor module and inspect processor socket, and replace if required. If the
issue persists, contact your service provider.
Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5150
Server
Administrator
Trap ID
VLT401
Message Unable to readarg1sensor value.
Arguments
• arg1 = sensor name
Detailed
Description
A voltage sensor identified in the message may have failed. This condition can
cause system performance issues and degradation in the moitoring capability of
the system.