Reference Guide

Recommended
Response
Action
No response action is required.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2177
Server
Administrator
Trap ID
115100
BAT1004
Message The battery onarg1learn cycle has timed out.
Arguments
arg1 = controller name
Detailed
Description
The controller battery must be fully charged before the learn cycle can begin. The
battery may be unable to maintain a full charge causing the learn cycle to timeout.
In addition, the battery must be able to maintain cached data for a specified period
of time in the event of a power loss. For example, some batteries maintain cached
data for 24 hours. If the battery is unable to maintain cached data for the required
period of time, then the Learn cycle will timeout.
Recommended
Response
Action
Replace the battery pack. The battery is unable to maintain a full charge.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2178
Server
Administrator
Trap ID
115300
32