Reference Guide
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2344
Server
Administrator
Trap ID
120300
VDR55
Message arg1initialization has failed.
Arguments
• arg1 = VD Name
Detailed
Description
The controller cannot communicate with attached devices. A disk may be removed
or contain errors. Cables may also be loose or defective.
Recommended
Response
Action
Verify the health of attached devices. Review the Alert Log for significant events.
Make sure the cables are attached securely. See the Cables Attached Correctly
section for more information on checking the cables.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2345
Server
Administrator
Trap ID
120400
VDR58
Message Bad block medium error is detected at blockarg1onarg2.
Arguments
• arg1 = args
• arg2 = VD Name
Detailed
Description
Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or
more member physical disks.
316