Reference Guide
physical disk and the target disk with redundant data have failed. A rebuild is not
possible because there is no longer redundancy.
Recommended
Response
Action
Replace the failed disks and restore from backup.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2310
Server
Administrator
Trap ID
120400
VDR50
Message Background Initialization (BGI) completed with uncorrectable errors onarg1.
Arguments
• arg1 = virtual disk
Detailed
Description
The background initialization task encountered errors that cannot be corrected.
The virtual disk contains physical disks that have unusable disk space or disk errors
that cannot be corrected.
Recommended
Response
Action
Review other messages to identify whether the physical disk that has errors. If the
virtual disk is redundant, you can replace the physical disk and continue using the
virtual disk. If the virtual disk is non-redundant, you need to recreate the virtual disk
after replacing the physical disk. After replacing the physical disk, run a consistency
check to verify the data.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2340
Server
Administrator
Trap ID
120400
313