Reference Guide

Server
Administrator
Event ID
5701
Server
Administrator
Trap ID
BAT1000
Message Battery onarg1is missing.
Arguments
arg1 = controller name
Detailed
Description
The controller cannot communicate with the battery. The battery is absent or
improperly connected. A battery with a weak or depleted charge may also cause
this message.
Recommended
Response
Action
Verify that the device is present and then check the cables. See the storage
hardware documentation to verify cabling. In addition check the connection to the
controller battery and the battery health. A battery with a weak or depleted charge
may cause this message.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2264
Server
Administrator
Trap ID
75300;80300;85300;90300;95300;100300;105300;110300;115300;120300
BAT1001
Message Battery onarg1was replaced.
Arguments
arg1 = controller name
Detailed
Description
A controllers battery was replaced.
Recommended
Response
Action
No response action is required.
Category Storage
30