Reference Guide
Category Storage
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2100
Server
Administrator
Trap ID
105300
TMP1001
Message arg1has crossed the minimum warning threshold.
Arguments
• arg1 = tempsensor name
Detailed
Description
The enclosure is too cold.
Recommended
Response
Action
Check whether the thermostat setting is too low and whether the room
temperature is too cool.
Category Storage
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2101
Server
Administrator
Trap ID
105300
TMP1002
Message arg1has exceeded the maximum failure threshold.
Arguments
• arg1 = tempsensor name
Detailed
Description
The enclosure is too hot. A variety of factors can cause the excessive temperature.
For example, a fan may have failed, the thermostat may be set too high, or the
room temperature may be too hot.
286