Reference Guide

Server
Administrator
Event ID
5054
Server
Administrator
Trap ID
5054
TMP505
Message Thearg1sensor has failed with a value ofarg2degrees Celsius.
Arguments
arg1 = sensor name
arg2 = temperature
Detailed
Description
The temperature sensor identified in the message has failed.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider.
Category System Health
SubCategory TMP = Temperature
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5055
Server
Administrator
Trap ID
5055
TMP1000
Message arg1exceeded the maximum warning threshold.
Arguments
arg1 = tempsensor name
Detailed
Description
The enclosure is too hot. A variety of factors can cause the excessive temperature.
For example, a fan may have failed, the thermostat may be set too high, or the
room temperature may be too hot.
Recommended
Response
Action
Check for factors that may cause overheating. For example, verify that the
enclosure fan is working. You should check the thermostat settings and examine
whether the enclosure is located near a heat source. Make sure the enclosure has
enough ventilation and that the room temperature is not too hot. Refer to the
enclosure documentation for more diagnostic information.
285