Reference Guide
Arguments
• arg1 = sensor name
• arg2 = temperature
Detailed
Description
The temperature sensor identified in the message is faulty, or the temperature
exceeds the warning threshold. This condition can cause system performance
issues and degradation in the moitoring capability of the system.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider. Otherwise, change the warning threshold for the
temperature sensor (if applicable) such that it corresponds to the hardware
configuration.
Category System Health
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5053
Server
Administrator
Trap ID
5053
TMP504
Message Thearg1sensor has detected an error with a value ofarg2degrees Celsius.
Arguments
• arg1 = sensor name
• arg2 = temperature
Detailed
Description
The temperature sensor identified in the message is faulty, or the temperature
exceeds the critical threshold. This condition can cause system performance issues
and degradation in the moitoring capability of the system.
Recommended
Response
Action
Review system power policy, check system logs for temperature related failures.
Category System Health
SubCategory TMP = Temperature
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
284