Reference Guide
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2155
Server
Administrator
Trap ID
105100
TMP500
Message Thearg1sensor has failed with value thearg2degrees Celsius.
Arguments
• arg1 = sensor name
• arg2 = temperature
Detailed
Description
A temperature sensor identified in the message has failed. This condition can cause
system performance issues and degradation in the moitoring capability of the
system.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider.
Category System Health
SubCategory TMP = Temperature
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5050
Server
Administrator
Trap ID
TMP501
Message Unable to read thearg1sensor value.
Arguments
• arg1 = sensor name
Detailed
Description
A temperature sensor identified in the message has failed. This condition can cause
system performance issues and degradation in the moitoring capability of the
system.
282