Reference Guide
SubCategory SYS = System Info
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5012
Server
Administrator
Trap ID
SYS115
Message The power cord sensor is non-functional.
Detailed
Description
The power cord sensor becomes non-functional because of one of the following
reasons: 1) The power cable may not be connected properly or disconnected. 2)
The power cord sensor in the power supply unit has failed. However, the power
supply unit may still function. 3) There is an input power failure.
Recommended
Response
Action
Do of the following to resolve the issue: 1) Reconnect the power cord to the power
supply unit. 2) Replace the power supply unit that has the failed power cord sensor,
with a new power supply unit. 3) Make sure that the input power supply is restored.
Category System Health
SubCategory SYS = System Info
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
Server
Administrator
Trap ID
SYS116
Message Unable to determine the status of the power cord.
Detailed
Description
The status of the power cord cannot be determined because of one of the
following reasons: 1) The power cable may not be connected properly or
disconnected. 2) The power cord sensor in the power supply unit has failed.
However, the power supply unit may still function. 3) There is an input power
failure.
278