Reference Guide

STOR0201
Message Unable to determine whether the system has the minimum required versions of the
RAID controller drivers and firmware.
Detailed
Description
Unable to determine whether the system has the minimum required versions of the
RAID controller drivers.
Recommended
Response
Action
See the Readme file on the installation media for driver and firmware requirements.
If Storage Services experiences performance problems, make sure that minimum
supported versions of the drivers and firmware are installed. For a list of correct
driver and firmware versions, contact the service provider.
Category Storage
SubCategory STOR = Storage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2164
Server
Administrator
Trap ID
10100
STOR0202
Message The configuration file (Path:arg1) that contains firmware and driver information
forarg2is not updated or is incorrectly formatted to complete the comparison.
Arguments
arg1 = file path
arg2 = controller name
Detailed
Description
Storage Services is unable to determine whether the system has the minimum
required versions of the RAID controller firmware and drivers because a
configuration file is not readable, corrupted, or has missing data.
Recommended
Response
Action
Reinstall Server Administrator and Storage Services.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
263