Reference Guide
Recommended
Response
Action
Identify and replace the failed components. To identify the failed component,
select the Storage object and click the Health subtab. The controller status
displayed on the Health subtab indicates whether a controller has a failed or
degraded component. Click the controller that displays a Warning or Failed status.
This action displays the controller Health subtab which displays the status of the
individual controller components. Continue clicking the components with a
Warning or Failed status until you identify the failed component. See Storage
Health for more information. See the enclosure documentation for information on
replacing enclosure components and for other diagnostic information.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2123
Server
Administrator
Trap ID
130600
STOR0200
Message Array Manager is installed on the system.
Detailed
Description
Installing Storage Services and Array Manager on the same system is not a
supported configuration. Storage Services is not installed on a system where Array
Manager is installed.
Recommended
Response
Action
Uninstall either Storage Services or Array Manager and retry the operation.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2135
Server
Administrator
Trap ID
10300
262