Reference Guide
Server
Administrator
Event ID
5304
Server
Administrator
Trap ID
5304
RDU0012
Message Power supply redundancy is lost.
Detailed
Description
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
The system was previously operating in a power redundant mode.
Recommended
Response
Action
Check the event log for power supply failures. Review system configuration and
power consumption.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 1 (Critical)
LCD Message Lost PSU redundancy. Check PSU cables
Server
Administrator
Event ID
5306
Server
Administrator
Trap ID
5306
RDU0013
Message Power supply redundancy is degraded.
Detailed
Description
The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
The system was previously operating in a power redundant mode.
Recommended
Response
Action
Check the event log for power supply failures. Review system configuration and
power consumption.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 2 (Warning)
LCD Message PSU redundancy degraded. Check PSU cables
241