Reference Guide

SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5354
Server
Administrator
Trap ID
5354
PSU0914
Message A predictive failure detected on power unitarg1.
Arguments
arg1 = number
Detailed
Description
Status from the power supply indicates a power supply exception occurred. The
power supply will try to operate. System Performance and power redundancy may
be degraded or lost.
Recommended
Response
Action
Remove input power and re-install supply at the next service window.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5353
Server
Administrator
Trap ID
5353
PSU1000
Message Power supply cable has been removed fromarg1.
Arguments
arg1 = PSU Sensor Name
Detailed
Description
The power supply unit is not receiving input AC power. The power cable may not
be connected properly or removed. This can happen if there is an AC failure or
problems with the power strip attached to the enclosure power supply.
233