Reference Guide

Server
Administrator
Event ID
5351
Server
Administrator
Trap ID
PSU0908
Message Power lost on power unitarg1.
Arguments
arg1 = number
Detailed
Description
The power supply is installed correctly but an input source is not connected or is
not functional.
Recommended
Response
Action
Verify the input source is attached to the power supply. Verify the input power is
within the operating requirements for the power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5354
Server
Administrator
Trap ID
5354
PSU0912
Message A failure detected on power unitarg1.
Arguments
arg1 = number
Detailed
Description
Status from the power supply indicates a power supply exception occurred. The
power supply will try to operate in a degraded state. System Performance and
power redundancy may be degraded or lost.
Recommended
Response
Action
Check input power. Re-install the power supply. If problem persists contact
support.
Category System Health
232