Reference Guide

PSU101
Message Power supplyarg1is not present.
Arguments
arg1 = power supply unit
Detailed
Description
The power supply unit identified in the message is not present, because of the one
of the following reasons: 1) The power supply unit is not correctly seated. 2) The
power cable may not be connected properly or diconnected. 3) The power supply
unit has failed. 4) There is an input power failure.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5353
Server
Administrator
Trap ID
5353
PSU102
Message Power suppyarg1status is unknown.
Arguments
arg1 = power supply unit
Detailed
Description
The status of the power supply unit identified in the message is unknown, because
of one of the following reasons: 1) The power supply unit is not correctly seated. 2)
The power cable may not be connected properly or diconnected. 3) The power
supply unit has failed. 4) There is an input power failure.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
231