Reference Guide
Detailed
Description
This power supply revision is not supported for this system.
Recommended
Response
Action
Review product documentation, change power supply with correct revision.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5354
Server
Administrator
Trap ID
5354
PSU100
Message Power supplyarg1is offline.
Arguments
• arg1 = power supply unit
Detailed
Description
The power supply unit identified in the message is offline, because of the one of
the following reasons: 1) The power supply unit is not correctly seated. 2) The
power cable may not be connected properly or diconnected. 3) The power supply
unit has failed. 4) There is an input power failure.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2)
Reconnect the power cable to the power supply unit. 3) Install a new power supply
unit 4) Restore the input power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5303
Server
Administrator
Trap ID
230