Reference Guide

Server
Administrator
Trap ID
PDR98
Message Command timeout occurred onarg1.arg2.
Arguments
arg1 = physical disk
arg2 = args
Detailed
Description
An error occurred while performing an action on the disk.
Recommended
Response
Action
Check the disk is present or replace the disk.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2405
Server
Administrator
Trap ID
90300
PDR100
Message Dedicated Hot Sparearg1no longer useful for all arrays.
Arguments
arg1 = PD Name
Detailed
Description
The controller is not able to communicate with a disk that is assigned as a
dedicated hot spare. The disk may have been removed. There may also be a bad or
loose cable.
Recommended
Response
Action
Verify that the disk is healthy and that it has not been removed. Check the cables.
See the Cables Attached Correctly section for more information on checking the
cables. If necessary, replace the disk and reassign the dedicated hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
217