Reference Guide

PDR76
Message Copyback not possible as SAS or SATA mixing is not supported.
Detailed
Description
Copyback not possible as SAS or SATA mixing is not supported in the same virtual
disk. This alert is provided for informational purposes.
Recommended
Response
Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
2200
Server
Administrator
Trap ID
90300
PDR88
Message Power state change failed onarg1. (fromarg2toarg3)
Arguments
arg1 = PD Name
arg2 = state
arg3 = state
Detailed
Description
When physical drives in spun down power state are configured, the drives should
transition to spun up power state.. If the drive is not functioning properly, this
transition could fail.
Recommended
Response
Action
Replace the physical disk and try again. Contact technical support if the issue
persists.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
216