Reference Guide

Detailed
Description
The current sensor identified in the message is faulty or the current drawn by the
system exceeds the warning threshold. This condition can cause system
performance issues and degradation in the moitoring capability of the system.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider. Otherwise, change the warning threshold for the current
sensor such that it corresponds to the hardware configuration.
Category System Health
SubCategory AMP = Amperage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5203
Server
Administrator
Trap ID
5203
AMP404
Message Thearg1sensor detected an error with a value ofarg2A.
Arguments
arg1 = sensor name
arg2 = current
Detailed
Description
The current sensor identified in the message is faulty or the current drawn by the
system exceed the critical threshold. This condition can cause system performance
issues and degradation in the moitoring capability of the system.
Recommended
Response
Action
Review system power policy, check system logs for power related failures, and
review system configuration changes. For more information, contact your service
provider.
Category System Health
SubCategory AMP = Amperage
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Server
Administrator
Event ID
5204
Server
Administrator
Trap ID
5204
21